Rockfon ceiling grid installation instructions Grid Installation Main runner Cross tee Hanger Installation requirements Welcome to the official Rockfon YouTube channel! We’re the world’s leading acoustic company – and our mission is to keep things quiet. Rockfon North America 4849 S. Performance Properties: Ceiling trim can be straight or curved in the horizontal axis Chicago Metallic Aluminum Cap 260/280 15/16 Exposed, Fire Rated ceiling grid is made from HDG steel with a 100% aluminum cap. Always carry the grid boxes on the ends to avoid any impact This extruded aluminum trim creates an attractive, smooth, rust and distortion free perimeter for finishing a ceiling or acoustic island. We offer three different Rockfon Mono Acoustic ceiling panels for different installation purposes: n Rockfon Mono Acoustic TE n Rockfon Mono Acoustic TE Direct n Rockfon Mono Acoustic TE Flecto. The ceiling system is versatile; it can be installed as a suspended ceiling using our Chicago Metallic™ T24 click 2890 suspension set, and with the click Rockfon-Chicago Metallic 640 (Hook) 660 (Stab) Non-Fire Rated Drywall Grid System-fire rated gypsum drywall suspension system-Specification Subject Technical specification information for gypsum drywall ceiling suspension system including fire rated ceiling assemblies, warranty, standard, and material information. The Ceilings & Interior Systems Construction Association (CISCA) lists 30 acoustical ceiling grid tools in its Ceiling Systems Handbook. Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. The hourly rating assigned to grid components, or the ceiling grid systems, cannot be achieved independent of the ceiling assembly of which it is part. com 2 Rockfon’s hold down clips are designed to work with all Chicago Metallic ® suspension systems and many Rockfon specialty metal ceilings. Record any shipping damage on the carrier’s bill of lading and contact ROCKFON immediately to order replacement Main runners in Rockfon System XL T24 A, E are installed at 1800 mm centres which provides a quick, easy and cost effective installation. Contact us to learn more. However, if e. This design approach can decrease the cost of the ceiling and allows for greater aesthetic flexibility. Do's . Rockfon Mono Acoustic TE Direct is meant only for Document Library Find all your essential documents in one place. These concealed snap-in metal ceiling tiles create a smooth, streamlined look while being completely recyclable at end of life. We offer three different Rockfon Mono Acoustic ceiling panels for different installation purposes: n Rockfon Mono Acoustic TE n Rockfon Mono Acoustic TE Direct n Rockfon Mono Acoustic TE Flecto Rockfon Mono Acoustic TE installs onto Chicago Metallic ™ drywall suspension. Grid. Barrier Board is installed above Rockfon, suspended, stone wool, acoustic ceilings and over interior partitions, it increases the sound isolation rating and speech privacy between rooms. Acoustic ceiling installation and most commercial suspended ceiling constructions consist of metal channels in the shape of an upside-down T. These hold down clips provide better tile retention by mitigating the effects of impact and uplift. Main runners are installed at the industry standard 48” o. Visible grid and semi-concealed grid ceiling Rockfon System T24 A is a 24mm wide visible grid ceiling system mean ing that your acoustic ceiling tiles rests on t he grid and that the acoustic ceiling tile edge doesn’t cover the grid. 2 Install grid suspension - The installation of 9/16" and 15/16" grid suspension should follow industry standard layouts for 2x2 and 2x4 grid modules. Grid Installation Main runner Cross tee Hanger Installation requirements a) Install after completion of above ceiling work. Excellent sound absorption with NRC 0. These items will confirm ceiling layout, panel sizes and finish, ceiling accessories, ceiling fixture layout and orientation, and any special edge conditions. Perimeter trim integrates with standard grid suspension systems and Rockfon specialty metal ceilings. +1-800-323-7164 I cs@rockfon. This drop ceiling grid features demountable hook-end cross tees for a quick and easily assembly. 2700 x 1200 horizontal. Combining our grid with our seismic tested perimeter and separation joint solutions creates a complete solution that not only performs but also reduces installation time, speeds up inspection, saves on material and labor costs and improves the aesthetics of the finished Rockfon ROCKWOOL Limited T/A Rockfon 14th Floor, Chiswick Tower 389 Chiswick High Road London W4 4AL Tel: 020 8222 7457 Fax: 020 8222 7458 Rockfon System T24 X is a concealed ceiling system that provides an elegant, continuous ceiling expression and is used with X edge tiles. 150 mm 150 mm 150 600 mm 150 mm 600 mm 600 a) Install after completion of above ceiling work. Rockfon® Mono® Acoustic is an aesthetically pleasing seamless ceiling offering excellent sound absorption properties (up to NRC 0. Grid Installation Main runner Cross tee Hanger Installation requirements They can be installed during the very early stage of the build (when windows are not fully sealed). Office ceiling design can contribute to the bottom line in supporting employee productivity and job satisfaction. 2020 City of Los Angeles Building Code (LABC) 2. Rockfon-acoustical ceiling edge finish-Infinity Perimeter Trim-Installation Guide Subject: Installation details for Rockfon Infinity acoustical clouds and ceilings perimeter trim including use of corner kits, integrating with ceiling grid and splice plates, how to cut edge trim, and using grid attachment clips. ) TIP: Cut the top of the grid first with tin snips INSTALLATION GUIDE-Ceiling system with a 24 mm wide visible grid with A edge tiles or recessed with E edge tiles - Easy and quick installation - Ease of service integrations due to 38mm equal height main runners and cross tees - Every tile is demountable and fewer hangers allow easy access to the plenum Visible/Semi-concealed ceiling system Grid layout Rockfon VertiQ A edge panels can be installed in Rockfon System VertiQ T24 Wall. Rockfon CDX and SCD edges are available in white and Rockfon ® Rockfon® System T24 A, E ™ 5 Grid layout and hanger location Rockfon A and E edge tiles can be installed in Rockfon System T24 A, E. In Rockfon System T24 A the Chicago Metallic T24 Click 2890 grid benefits from a click system providing quick and easy installation and demounting. The correct way to specify ceilings for each of these different roles is explained. Rockfon® Hygienic Plus™ tiles are ideal for hygienic or cleanroom ceiling applications due to their cleanability and low particle emission for better air cleanliness. Created Date: 11/30/2017 12:52:02 PM This drop ceiling grid features seismically compliant stab-end cross tees for quick assembly and strong connections. It’s also recommended that the ceiling mechanic(s), as well as other tradespersons, make certain their hands are clean when handling elegant, seamless ceiling. In addition to serving as the framework for dropped ceiling tiles, suspension systems also can be specified for drywall installations. These metal ceiling panels are available in a wide variety of sizes and finish options including painted colors, metals and wood-look finishes. Rockfon® Hygienic Plus™ tiles inhibit the growth of MRSA and are tested per ASTM D4828 for washability, ASTM D2486 for scrub resistance, and ASTM D1308 for chemical resistance. Industry Standard Documentation n ASTM C636 (Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Hygienic ceiling tiles, panels and systems meet clean room and cleanliness requirements for both dry and humid environments. com -Sits on top of the grid members for easy attachment-Hidden design provides clean look on finished ceiling installation-Our 1494 clip can be used on the main runners and cross tees to minimize inventory needs-Completely maintains ceiling system strength-Hash mark on clips easily identify screw attachment points in the field Chicago Metallic® 200 Hook Grid™ 15/16" Exposed grid ceiling system is available in intermediate and heavy-duty designs, non-fire rated and fire rated construction, and is built with HDG 30 steel. The acoustic performance levels in the building design standards and how ceilings contribute to compliance are covered. Install your perimeter trims around your room at the correct height Position and fix your suspension hangers Install the main runners Install the cross tees and fit the ceiling tiles to it Checklist . For more installation details, reference the Rockfon installation guide for CDX/SCD. The grid modules should match the panel sizes of 2x2 or 2x4. This guide will cover the hold down clips we offer, and provide application and installation details. . Research conducted by Rockfon® and NGC Testing Services shows that a lightweight plenum barrier made of stone wool insulation can provide an STC/CAC 45 level of blocking when combined with a stone wool ceiling system. For any space that requires plenum access, acoustic performance, and health and safety benefits, choose a ceiling tile grid that supports Rockfon stone wool acoustic ceiling tiles and panels, specialty metal and wood ceiling solutions. Easy to install. (up to NRC 0. Beyond these 30 basic ceiling grid tools, there are very few specialty tools for acoustical ceiling installation that should be necessary. This option can decrease the cost of the ceiling and allow for greater aesthetic flexibility. Rockfon® System dB T24 A E ™ 2 3 5 7 4 2 1 A,2 ° 10 E24L 6/8 E24S 6 38 mm full height main runners and cross tees for stability and easy service integration. Rockfon® System T24 X ™ X-edge INSTALLATION GUIDE - Versatile and simple ceiling system suitable for humid and harsh indoor environments such as swimming pools, kitchens and sanitary areas - Corrosion resistance Class D (EN 13964) - Visible and semi-concealed grid ceiling system - Every single tile is demountable for easy and fast access to Rockfon System T24 X is a concealed ceiling system that provides an elegant, continuous ceiling expression and is used with X edge tiles. Prior to beginning installation ensure that all materials are received and in good condition. Our Torsion Spring Plus panels are available in widths up to 4’ and lengths up to 10’. c) Install Infinity perimeter trim in accordance with manufacturers printed instructions and details and approved shop drawings. The CISCA Ceiling Systems Handbook includes proper methods of installing ceiling tile grid, drop ceiling grid and suspended ceiling grid, among other types of suspension systems for exposed, concealed and specialty metal systems. g. b) Install ceiling suspension system as specified and in accordance with ASTM C636. c. Performance, easy installation, multiple grid options and seismic performance are achieved with ceiling grids from Rockfon Chicago Metallic®. This includes the requirement of seismic restraint using downposts as prescribed in Rockfon North America 4849 S. The field grid is installed following the practices outlined in ASTM . Learn about cutting ceiling tiles, how to hang ceiling tiles, and tips and tricks for installing ceiling tiles. and there is a need for the ceiling tiles to have been tested in accordance with ISO 14644-1, or it is requested by a client that all cut edges should be repainted, the cut edge(s) of the tiles Rockfon® System T15 A, E ™ 5 Grid layout and hanger location Rockfon A-edge (600 x 600) and E-edge (600 x 600, 1200 x 600) tiles can be installed in Rockfon System T15 A, E. Both systems provide 100% downward accessibility (unless penetrations exist). Learn more. The dropped ceiling grid layout may be exposed or concealed. The system can either be installed as a suspended ceiling at the desired height using the Chicago Metallic T24 Click 2890 grid or installed directly to the soffit by using direct fixing brackets. Rockfon grid suspension systems comply with 2 codes per ICC ESR-2631 Report: 1. Reliable and easy to install, they pair well with our complete assortment of ceiling panels. Performance Properties: Chicago Metallic® 200 Hook Grid™ 15/16" Exposed grid ceiling system is available in intermediate and heavy-duty designs, non-fire rated and fire rated construction, and is built with HDG 30 steel. Field Installation. com | rockfon. Some layout options are shown below depending on the size of the tile. For any space that requires plenum access, acoustic absorption, and health and safety benefits, choose a ceiling tile grid that supports Rockfon stone wool tiles and panels, and specialty metal ceiling solutions. and there is a need for the ceiling tiles to have been tested in accordance with ISO 14644-1, or it is requested by a client that all cut edges should be repainted, the cut edge(s) of the tiles However, if e. com Office ceiling tiles, acoustic panels, grid and suspended ceiling systems can have a dramatic impact on creating workplaces that provide a good sound experience, sustainable design and attractive interior. Suspension Grid Installation. 95). With Rockfon System XL T24 A, E, 33 % less hangers are needed for installation and 33 % of levelling work is eliminated compared to a traditional T24 visible/semi-concealed grid ceiling system. Austin Ave. Our document library includes documents such as brochures, case studies, product datasheets, installation guides, specifications and Environmental Product Declarations (EPDs). Refer to project drawings for panel layout, if available. During Installation To avoid damaging the painted and reflective surface of ceiling components during installation, it’s advisable to maintain as clean a work environment as possible. Rockfon Eclipse is available in a variety of shaped formats with a clean minimalistic A edge and an unlimited custom colour range using NCS Quick and easy to install, Rockfon Eclipse can be used alone or where a traditional suspended ceiling cannot be installed Rockfon® System T24 A, E ™ 5 Grid layout and hanger location Rockfon A and E edge tiles can be installed in Rockfon System T24 A, E. Rockfon Hygienic® Plus tiles are being used in designated clean room areas which have to operate in accordance with ISO 14644 etc. Ideal for both straight or curved ceiling edges, this attractive, smooth, rust- and distortion-free extruded perimeter trim integrates with standard suspension systems and other specialty metal ceiling systems. 1. Grid Installation Rockfon VertiQ panel J-channel (40 mm) T-Profile Supporting bracket T-fixing bracket SMF-clip 2. ” 1 May 12, 2020 ยท In this step-by-step video, we show you how to install our Rockfon® System T24 A™. Installation of a suspended ceiling – how to install suspended ceiling grid. Chicago, IL 60638 1-800-323-7164 cs@rockfon. 150 mm 150 mm 150 600 mm 150 mm 600 mm 600 Performance Properties. Simply stated, this course is everything you need to know about selecting and specifying acoustic ceilings to achieve improved IEQ. Hanger wire spacing should not exceed the design’s stated center spacing but may be less than specified. Our noise-absorbing systems, ceilings, and walls soften Our Chicago Metallic acoustical grid systems offer a wide range of high performance suspension system solutions. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. The system is used to create a visible grid ceiling system and can be inst Suspended acoustic ceiling installation with tiles can be a quick and easy process with the right panels, properly installed suspension systems and being equipped with the right tools. d) Infinity perimeter trim to be supported by ceiling grid suspension system. Always follow good safety practices when installing ceilings. Rockfon SCD edge tile is a semi-concealed system that provides a more monolithic-looking ceiling than traditional reveal tiles, leaving a 1/4” reveal between tiles. The ideal applications are when the suspended ceiling grid runs continuously over the tops of interior partitions or when pre-manufactured, ® Ceiling Products 1. Installation methods of ceiling suspension systems on commercial buildings are enforced by ASTM C636 “Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels. beginning the installation of this metal ceiling system. (This creates the proper border tile opening. Research conducted by Rockfon and NGC Testing Services shows that a lightweight plenum barrier made of stone wool insulation can provide an STC/CAC 50 level of blocking when combined with a stone wool ceiling system. Grid layout Rockfon VertiQ A edge panels can be installed in Rockfon System VertiQ T24 Wall. Chicago Metallic™ grid systems are third party certified to meet ASTM standards and are listed in ICCES Evaluation Services, reference report ESR-2631 for more information. Rockfon® Spanair® Torsion Spring Concealed Metal Panels install easily, using a grid-based suspension system, in an interior, exterior and seismic D, E, F application areas. Rockfon ROCKWOOL Limited T/A Rockfon 14th Floor, Chiswick Tower 389 Chiswick High Road London W4 4AL Tel: 020 8222 7457 Fax: 020 8222 7458 Rockfon® Planostile™ Snap-in Metal Panel Ceiling System is approved for installation in seismic D, E, F applications and can be used in both interior and exterior spaces. How to Install Your Armstrong ® Suspended Ceiling INSTALL GRID Prepare and Hang Main Beams • To prepare the first main beam, trim the end of the main beam so that a cross tee slot on the main beam is the border panel distance from the wall (B). The plenum depth stated in each design represents the minimum acceptable plenum depth. C636 and ASTM E580 and must conform to all local building codes and standards. These upside-down T’s are commonly referred to as mains runners or cross runners/cross tees and are suspended on wires from the overhead structure, creating a space between the buildings structure and the finished ceiling called a plenum. Ceiling grids from Rockfon Chicago Metallic® combine trusted performance, easy installation, multiple grid options & seismic capabilities. 2019 California Building Code 102422 USA and Canada: Tel. com In the event of an earthquake, our seismic-rated ceiling systems help support life safety and the preservation of property. Suspended ceiling tile installation relies on the support network provided by the metal ceiling suspension system. 90 that helps create healing environment Has a low particle emission achieving ISO Class 4 per ISO 14644-1 with Chicago Metallic® BarrierGrid® for better air cleanliness The system can be either installed as a suspended ceiling at the desired height using Chicago Metallic T24 Click 2890 or mounted directly to the soffit using direct fixing brackets. Performance Properties: Suspended ceiling perimeter trim is made from sturdy extruded aluminum Rockfon® Planostile™ Lay-in Metal Panel Ceiling System is durable and versatile metal panel ceilings available in square, reveal and flush reveal options. Some layout options are shown below depending on the size of the panel. xnj hseppxq bpkb oibd ygft gnlyt jscv icnbp ipnrk nicf